drop volt test
nice sunny day so got out there
battery voltage 12.6v
B wire test 12.6 then 0.2 volts when cranked---so that looks good
(Batt positive terminal to B wire post on starter)
Ground test 0.01 test and 0.01 volts when cranked---so that looks good
(Batt negative terminal to nut on starter)
S (switch connection on relay red wire) - couldn't get a voltage here from positive battery terminal to S connection on relay. could however get a 12.6 volt reading if i took reading between negative battery terminal and S and a reading of 10.7 when cranked.
So something is not right.
here is video i followed
https://www.youtube.com/watch?v=WMXENKujYtc
here is a quick test from battery negative to S wire in connection to relay. Does this make sense? Ignition is off.
https://ibb.co/XxYLVg8
|