engel up date
Rang Mark Horner at Engel uk gave me some advice about seeking the fault he said "
The first thing to check is whether the little circuit breaker inside the fridge has popped out this is found just below the Thermostat and is a little red button. If this is ok then you need to check whether there is any power getting to the Compressor.
To do this you need to remove the push on connector off of the bottom of the Compressor (this will be a yellow wire) and check whether there is voltage there. It should range between 10 & 20 volts AC. If you have this voltage then it would be that the Compressor would of failed. If the voltage is not correct then it would be the Electronic power supply that would of failed.
the power unit has failed amd hes gonna send me new one great service so far