I don't have TT600 info to hand, so stand to be corrected.
From the diagram you've posted and your results, in both sets of measurements you've effectively measured the secondary, which is 13.74k, so that's OK. (Spec is 13k + or - 20%)
To measure the primary, connect to the two spade connectors, which I assume are the red/white and orange you refer to.
Switch to the 200 range.
The reading should be 4, + or - 15%.
That is, between 3.4 and 4.6.
When measuring this low a resistance, make sure the connections between coil and Ohm meter are clean and firm, as a dodgy connection can alter the reading.
Also, check the battery in your meter is OK (normally there'll be an indicator to show if it isn't).
Hope that helps.
|