Hi All,

Just got back from a trip to Mt Ararat with a couple of German mates one of which was riding a R100GS. On the way he stopped for a break and tried to restart the engine. The starter motor turned over but there was no spark at the plugs. Is there a known electrical part weakness that could be the likely cause of this problem? I'm trying to get some info because the bike is still stuck here in Turkey.

Many thanks,

Dicky
Reply With Quote
  #2  
Old 30 Aug 2010
Registered Users
HUBB regular
 
Join Date: Nov 2007
Location: Belgium
Posts: 69
I know that the alternators on these bikes can be prone to problems.

It's quite common to have to take them apart and repair/replace bits, you start there.

David
Reply With Quote
  #3  
Old 30 Aug 2010
John Ferris's Avatar
Gold Member
Veteran HUBBer
 
Join Date: Feb 2001
Location: Reno,NV,USA
Posts: 555
I think the coil would be the first thing I would look at.
Check all the connections ar the coil.
The input is a small plug that powers both outputs that would stop both plugs from firing.
Reply With Quote
  #4  
Old 31 Aug 2010
Vaufi's Avatar
Contributing Member
Veteran HUBBer
 
Join Date: Jan 2004
Location: Munich, the beer capital
Posts: 769
Check whether the coil is perfectly dry. If you're driving in the rain and the coil has a minute crack, you won't get a proper spark. The coils tend to crack after a while...
__________________
Only when we pause to wonder
do we go beyond the limits of our little lives.
(Rod McKuen)
Reply With Quote
  #5  
Old 31 Aug 2010
Registered Users
HUBB regular
 
Join Date: Jan 2008
Location: colchester uk
Posts: 54
Quote:
Originally Posted by Vaufi View Post
Check whether the coil is perfectly dry. If you're driving in the rain and the coil has a minute crack, you won't get a proper spark. The coils tend to crack after a while...
yes, i had this problem on my R65. wd40 and duct tape fixed it while on the road.check this first maybe.
Reply With Quote
  #6  
Old 31 Aug 2010
AliBaba's Avatar
Registered Users
Veteran HUBBer
 
Join Date: Apr 2001
Location: Norway
Posts: 1,271
The system consist of three parts that can be faulty (and all the wires and spark-plugs of-course)

For all the tests turn ignition on a few seconds before you do the test.

Various testpoints:
  • Check kill-switch
  • Green wire on coil: 12V
  • Green/Blue wire (4/15) on ignition-module: 12V
  • Brown wire (2/31) on ignition module: 0V

Coil:
  • Remove the black wire
  • Connect a lead to where the black wire was and short this to ground.
  • There should be a spark every time, if not the coil is faulty

Ignition-module:
  • Find the three-pin connector located underneath the starter cover (Brown, Blue Green/Yellow)
  • Disconnect the plug
  • Short the brown wire in the female plug to earth
  • There should be a spark every time, if not the module is faulty
  • Connect the plug.

Hallsensor:
  • Put a voltmeter between 12V and the brown wire in the previous mentioned three-pin connector (the plug has to be connected).
  • Rotate the engine and se that you get a reading in the area 6-12V every time the swingwheel passes the S-mark
Reply With Quote
  #7  
Old 31 Aug 2010
Registered Users
Veteran HUBBer
 
Join Date: May 2008
Location: SW France
Posts: 160
I've never suffered this type of failure on an R80/but was told that the ignition module was the most prone to sudden failure, so I carry a spare (that I should test sometime). Coils breakdown and cause a misfire but rarely fail completely and whilst other hall effect trigers fail from time to time it's apparently very rare with the BMW one.
Reply With Quote
  #8  
Old 31 Aug 2010
Registered Users
Veteran HUBBer
 
Join Date: Oct 2005
Location: Norwich,Ontario,Canada
Posts: 658
Excellent summary by Ali Baba covers all posibilities.
Just to add one point though. - just because there is indication of a spark at each correct firing point does not of itself ensure that the spark is powerful enough. I had such a problem once on my R80GS The motor refused to fire and only gave sporadic pops. . A shop which used to deal BMW could not trace the problem . Then at another official BMW service point with more diagnostic tools it was determined that the ignition coil was bad, the sparks were too weak to cross the gap in a cylinder under compression. Replacement of the coil with a new unit solved the problem .
Reply With Quote
  #9  
Old 31 Aug 2010
Registered Users
Veteran HUBBer
 
Join Date: Oct 2002
Location: Stockholm - Sweden
Posts: 309
Quote:
Originally Posted by Dicky View Post
Hi All,

Just got back from a trip to Mt Ararat with a couple of German mates one of which was riding a R100GS. On the way he stopped for a break and tried to restart the engine. The starter motor turned over but there was no spark at the plugs. Is there a known electrical part weakness that could be the likely cause of this problem? I'm trying to get some info because the bike is still stuck here in Turkey.

Many thanks,

Dicky
Yes.
The ICU is broken. Renew.
This will work nicely:
Art.no.: 53-2600 = Bosch original on R80-100. Affordable - merely about 20,- EU -
Tändingssystem och Motorstyrning Audi 100 STYRENHET TÄNDNING - Biltema
Happen to me once - had tuned a R100. Just switched the ignition off. Checked all was ok. Turned the ignition back on again, but... the bike was now -dead- !
Took me about 8 h to figure-out what was wrong... it never dawned on me that the ICU would fail that suddenly...


OR - it may be, even though highly unlikely:


HT-lead failiure.
Do you have access to a multimeter-gauge?
Check secondary resistance by just pulling the sparkplugcaps off - measure across (cap to cap) - should read about 25kOhm.
Then pull the pluggs and measure them - they should read anything between 1-7kOhm.

It could also be a broken ground wire to the coils...

By the description you give I do not think the ITU have broken, but in case it has... expensive... Alibaba have given you a very good guide on how to locate the fault, what ever it may be.
Look up my thread " www.horizonsunlimited.com/hubb/bmw-tech/impulsgenerator-gone-bust-broken-itu-41532 " for further info on what to do if the ITU is broken.
Why I do not think it is broken is because you did not mention any of the cardinal symptoms of a bad hall-sensor, still it could be that the hallsensor just died on you...
__________________
Drive Safely,
Albert

Last edited by dc lindberg; 1 Sep 2010 at 13:49.
Reply With Quote
  #10  
Old 31 Aug 2010
Registered Users
Veteran HUBBer
 
Join Date: Jan 2003
Location: Kas,Antalya
Posts: 112
Dear All,

Very many thanks for taking the time and trouble to answer my queery. I've got loads to work with and will keep you posted.

Best wishes,

Dicky
Reply With Quote
  #11  
Old 22 Dec 2010
Synt's Avatar
Contributing Member
New on the HUBB
 
Join Date: Aug 2010
Location: Vienna, Austria
Posts: 19
Quote:
Originally Posted by Dicky View Post
Dear All,

Very many thanks for taking the time and trouble to answer my queery. I've got loads to work with and will keep you posted.

Best wishes,

Dicky
Dicky,
As I´m experiencing the same issuesbeing stranded :-) - what was your result?
Kind regards from Puerto Madryn, Argentina,
Synt
Reply With Quote
  #12  
Old 23 Dec 2010
Registered Users
Veteran HUBBer
 
Join Date: Jan 2003
Location: Kas,Antalya
Posts: 112
Quote:
Originally Posted by Synt View Post
Dicky,
As I´m experiencing the same issuesbeing stranded :-) - what was your result?
Kind regards from Puerto Madryn, Argentina,
Synt
The German mate whose bike it was had a load of new stuff shipped over from Germany including the Hall sensor, a CDI unit and goodness knows what else. A friend of his put it all back together and the bike worked. Unfortunately I have no idea which single part was at fault. Sorry about the reply to your pm but I had completely forgotten about the incident. I sincerely hope that other, wiser, heads will be along soon to help you out.


Cheers,

Dicky
Reply With Quote
  #13  
Old 24 Dec 2010
Registered Users
New on the HUBB
 
Join Date: Nov 2010
Location: Reading, England
Posts: 6
I have found the ICU to be very reliable, but I have had a failure with the insulation cracking on the old grey ignition coil. left me on the central reservation of the M25 at 1600 hrs Friday December evening. Oh Good.
Chile_bike is running a Ford Mondeo coil, the primary wired in series and the 2 secondries used to twin plug the beast, and it´s getting me fine to Ushuaia at the moment. The coil requires engineering to fit properly, if you jury-rig one of an old car - ENSURE THE COIL FRAME IS EARTHED....
If you are not twin plugged use just one primary and one secondry. Don´t run the coil without a load. I do know of a case with failed pickup coil, easily diagnosed with a meter, not so easily fixed. Don´t be frightened of electrics - it´s not wizardry.
sdk
Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 Registered Users and/or Members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
'97 TB3 electrical problem tackle Yamaha Tech 4 17 Mar 2010 20:08
bandit 400 gsf electrical problem bandit400 Suzuki Tech 0 3 Aug 2009 20:53
Electrical Problem !! big t Yamaha Tech 29 11 Apr 2008 05:39
yet another electrical problem magyver Yamaha Tech 15 2 Nov 2007 01:02
XR400 electrical problem colsan1 Honda Tech 2 14 Feb 2007 14:27


All times are GMT +1. The time now is 16:15.